A multi-mode cantilever singular point detection using adaptive hypothesis testing
Detekce singuárních bodů kmitavého nosníku s užitím adaptivního testování hypotéz
Abstract
Fundamental analysis of a multi-mode model of the atomic force microscope cantilever shows that at some points; called here singular points, the mode is vanished. Consequently, the order of the input/output behavior is reduced. The singular points can be detected comparing possible candidates on the best model order. The detection is then naturally performed by applying the Bayesian model comparison. Since the exact position of the singular points is not available a priori, an explicit model of updating the probability of tested hypotheses in time is built. More specifically, a mechanism of suppressing absolute information is suggested based on the Bayesian decision problem where the Kullback-Leibler divergence is used. Analýzou modelu kmitavého nosníku lze vypozorovat, že některé body, známé rovněž jako singulární body se mohou vzájemně překrývat. Toto překrytí změní vlastnosti vstupně výstupního chování systému a vede na redukci jeho řádu. Detekce těchto bodů tak může být realizována Bayesovským porovnáním několika hypotéz na nejlepší řád modelu.
Keywords
testování hypotéz, Bayesovské metody, adaptivní systémy, hypothesis testing, Bayesian methods, adaptive systemsPersistent identifier
http://hdl.handle.net/11012/137102Document type
Peer reviewedDocument version
Final PDFSource
Journal of Physics: Conference Series. 2015, vol. 633, issue 1, p. 1-4.http://iopscience.iop.org/article/10.1088/1742-6596/633/1/012057