Long-action of additional horizontal prestressing on masonry

Zobrazit/ otevřít
Datum
2017-07-20Altmetrics
10.1016/j.proeng.2017.04.525
Metadata
Zobrazit celý záznamAbstrakt
This article is focused on verifying behaviour of a brick masonry which was horizontally post-tensioned. An experimental model of three walls has been built for the measurement. The model is in scale 1:1 and represents a part of a real structure. Longitudinal strain of brick walls has been measured by wire strain gauges in important places. Surrounding temperature and temperature inside the walls were also recorded. Results of the experiment have been continuously evaluated and compared with the simplified numerical models. Right now we have a better picture of actual behaviour of the brick masonry wall which was horizontally prestressed and we are able to design appropriate restoration works for historical buildings.
Klíčová slova
addition prestressing, strain, brick walls, experimental measurementTrvalý odkaz
http://hdl.handle.net/11012/194766Typ dokumentu
Recenzovaný dokumentVerze dokumentu
Finální verze PDFZdrojový dokument
Procedia Engineering. 2017, vol. 195, issue 1, p. 67-72.https://www.sciencedirect.com/science/article/pii/S1877705817320775