Transient Effect at the Output of a Linear Dynamic System Controlled Pulse-Width Modulation

Loading...
Thumbnail Image
Date
2015
ORCID
Advisor
Referee
Mark
Journal Title
Journal ISSN
Volume Title
Publisher
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Abstract
The goal of this work is to determine the size of overshoot produced at the output of a linear continuous second order system controlled by pulse width modulation. This work contains the calculation of the output signal response of the system in the time domain using the Laplace transform. The calculations of the amplitude of the output signal based on the pulse width modulation and system parameters are performed in this work. Finally the possibilities were given to determine the suitable period of pulse width modulation for required ripple. All the important calculations were compared with the simulations in the MATLAB-SIMULINK program and with the measurement at the real inertia second order cell.
Description
Citation
Proceedings of the 21st Conference STUDENT EEICT 2015. s. 313-315. ISBN 978-80-214-5148-3
http://www.feec.vutbr.cz/EEICT/
Document type
Peer-reviewed
Document version
Published version
Date of access to the full text
Language of document
cs
Study field
Comittee
Date of acceptance
Defence
Result of defence
Document licence
© Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
DOI
Citace PRO