Wooden Facade and Determination of Strength of Bonded Timber Joints
Dřevěné fasády a pevnost lepeného spoje
Zusammenfassung
A research case focused on vented wooden façade system with bonded joints is presented in this paper. The potential of bonded joints is studied and described in more detail and verified through experimental measurements. For the purpose of tests spruce timber profiles were chosen for the load bearing substructure and Wooden plastic composite façade sheeting for the cladding. Three types of industrial adhesives intended for structural bonding were selected. The article is focused on the preparation as well as on the subsequent experimental verification of substructure bonding retention to the cladding. The adhesive bonds were tested both in tension as well as in shear at a temperature of (293.15+/-3) K and a relative humidity of (55+/-10) %. The test results proved the fact that bonded joints are more than suitable alternative to the mechanical joints. During the tests appeared some differences in stability and failure behaviour between the adhesive systems as well as within the sheeting material. Additionally, the suitability of selected group of adhesives in combination with wooden plastic cladding material as well as with the timber substructure was confirmed. A research case focused on vented wooden façade system with bonded joints is presented in this paper. The potential of bonded joints is studied and described in more detail and verified through experimental measurements. For the purpose of tests spruce timber profiles were chosen for the load bearing substructure and Wooden plastic composite façade sheeting for the cladding. Three types of industrial adhesives intended for structural bonding were selected. The article is focused on the preparation as well as on the subsequent experimental verification of substructure bonding retention to the cladding. The adhesive bonds were tested both in tension as well as in shear at a temperature of (293.15+/-3) K and a relative humidity of (55+/-10) %. The test results proved the fact that bonded joints are more than suitable alternative to the mechanical joints. During the tests appeared some differences in stability and failure behaviour between the adhesive systems as well as within the sheeting material. Additionally, the suitability of selected group of adhesives in combination with wooden plastic cladding material as well as with the timber substructure was confirmed.
Keywords
Lightweight façades, adhesion system, wooden composite façade cladding, adhesion, cohesion., Lightweight façades, adhesion system, wooden composite façade cladding, adhesion, cohesion.Document type
Peer reviewedDocument version
Final PDFSource
ARSA - Proceedings in ARSA - Advanced Research in Scientific Areas. 2014, vol. 3, p. 331-335.http://arsa-conf.com/archive/?vid=1&aid=2&kid=60301-72
Collections
Citace PRO
Solange nicht anders angezeigt, wird die Lizenz wie folgt beschrieben: Creative Commons Attribution-NonCommercial 4.0 International
Verwandte Dokumente
Anzeige der Dokumente mit ähnlichem Titel, Autor, Urheber und Thema.
-
Umělecká škola v Brně
Hlubinková, MonikaTématem projektu je návrh novostavby umělecké školy v lokalitě Brno-Střed, Veveří. Pozemek se nachází v klidové oblasti Kraví Hora poblíž Hvězdárny a planetária Brno. Návrh spočívá v zachování klidové oblasti vytvořením ... -
Sportovně rekreační centrum Brno - Královo Pole
Sysel, JakubBakalářská práce řeší jeden objekt, který svou funkcí rozšiřuje zázemí stávajícího sportovních areálu na ulici Vodova v Králově poli v městské části Brna. Budova stojí samostatně a přímo nesousedí s žádnou další budovou. ... -
Vědecko-technický park Roztoky - technologická etapa opláštění
Vyplel, MichalPředmětem této bakalářské práce je řešení technologické etapy opláštění Vědecko-technického parku Roztoky. Je zde popsán celkový postup realizace provětrávané fasády. Práce obsahuje technologický předpis montáže provětrávané ...