Thermal Bonds of Buildings Structures in Energy Conservation–A Case Study
Tepelné vazby stavebních konstrukcí při ochraně energií - případová studie
Abstract
From energy point of view, very actual topic in Czech Republic is redevelopment of concrete constructions in buildings.
The article describes theoretical and experimental evaluation of chosen thermal joints of particular building built from
reinforced concrete skeleton. The building stands in the central Europe in Brno. Problematic joints of reinforced concrete
construction with filling construction were identified using thermo-graphic method. Consequently method of numerical
simulation of steady state of heat transfer in 2D was used in software CalA. The aim was to evaluate linear coefficient of
heat transfer and to identify critically low temperatures on internal surfaces and the energy losses of chosen details. Sanace betonových konstrukcí budov z pohledu energetického je u budov starších 20-ti let aktuálním úkolem dneška. Příspěvek popisuje provedené teoretické a experimentální vyhodnocení vybraných tepelných vazeb konkrétní budovy postavené ze železobetonového skeletu MS-OB stojící v Brně. Problematická místa vazeb železobetonových konstrukcí na konstrukce výplňové byla identifikována termografickou metodou. Dále byla využita teoretická metoda numerické simulace časově ustáleného 2D sdílení tepla v softwaru CalA s cílem kvantifikovat lineární činitele prostupu tepla a identifikovat kriticky nízké teploty na vnitřních površích těchto vybraných detailů.
Keywords
thermal bonds, thermo-graphic method, numerical simulations, lineární tepelné vazby, termografická metoda, numerická simulacePersistent identifier
http://hdl.handle.net/11012/70199Document type
Peer reviewedDocument version
Final PDFSource
AASRI Procedia. 2012, vol. 2012, issue 2, p. 14-19.http://dx.doi.org/10.1016/j.aasri.2012.09.007