Experimental testing of the electromagnetic coil – determining the range of electromagnetic coil

Loading...
Thumbnail Image
Date
2018-07-16
ORCID
Advisor
Referee
Mark
Journal Title
Journal ISSN
Volume Title
Publisher
IOP Publishing
Altmetrics
Abstract
The principle of steel fibre reinforced concrete structures is a uniform distribution of steel fibers in the given volume (structure or structural element), which, however, is not always possible to guarantee in the production. This is closely related to a problem of performing diagnosis of the existing steel fibre reinforced concrete structures. Despite the fact that this material is not unknown, in the standards regulating quality control of the uniformity of fibre distribution, the assessment of distribution uniformity is still based on a destructive testing method. The paper describes a partial experiment which consisted in testing a proposed measuring device and in determining the depth of electromagnetic field range in the test specimens.
Description
Citation
IOP Conference Series: Materials Science and Engineering. 2018, vol. 385, issue 2018, p. 1-6.
http://iopscience.iop.org/article/10.1088/1757-899X/385/1/012029
Document type
Peer-reviewed
Document version
Published version
Date of access to the full text
Language of document
en
Study field
Comittee
Date of acceptance
Defence
Result of defence
Document licence
Creative Commons Attribution 3.0 Unported
http://creativecommons.org/licenses/by/3.0/
Citace PRO