Show simple item record

dc.contributor.authorVarmuža, Jancs
dc.contributor.authorKatovský, Karelcs
dc.contributor.authorZeman, Miroslavcs
dc.contributor.authorŠťastný, Ondřejcs
dc.contributor.authorHaysak, Ivancs
dc.contributor.authorHolomb, Robertcs
dc.date.accessioned2021-03-04T15:54:13Z
dc.date.available2021-03-04T15:54:13Z
dc.date.issued2018-04-18cs
dc.identifier.citationEPJ Web of Conferences. 2018, vol. 177, issue 01004, p. 1-6.en
dc.identifier.isbn2100-014Xcs
dc.identifier.issn2100-014Xcs
dc.identifier.other147212cs
dc.identifier.urihttp://hdl.handle.net/11012/196416
dc.description.abstractKnowledge of neutron energy spectra is very important because neutrons with various energies have a different material impact or a biological tissue impact. This paper presents basic results of the neutron flux distribution inside the new experimental research stand SVICKA which is located at Brno University of Technology in Brno, Czech Republic. The experiment also focused on the investigation of the sandwich biological shielding quality that protects staff against radiation effects. The set of indium activation detectors was used to the investigation of neutron flux distribution. The results of the measurement provide basic information about the neutron flux distribution inside all irradiation channels and no damage or cracks are present in the experimental research stand biological shielding.en
dc.formattextcs
dc.format.extent1-6cs
dc.format.mimetypeapplication/pdfcs
dc.language.isoencs
dc.publisherEDP Sciences - Francecs
dc.relation.ispartofEPJ Web of Conferencescs
dc.relation.urihttps://doi.org/10.1051/epjconf/201817701004cs
dc.rightsCreative Commons Attribution 4.0 Internationalcs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectneutron energy spectraen
dc.subjectexperimental research stand SVICKAen
dc.subjectbiological shieldingen
dc.subjectactivation detectorsen
dc.subjectneutron flux distributionen
dc.subjectirradiation channelsen
dc.titleNew experimental research stand SVICKA neutron field analysis using neutron activation detector techniqueen
thesis.grantorVysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. oddělení-EEN-CVVOZEcs
sync.item.dbidVAV-147212en
sync.item.dbtypeVAVen
sync.item.insts2021.03.04 16:54:13en
sync.item.modts2021.03.04 16:14:47en
dc.coverage.issue01004cs
dc.coverage.volume177cs
dc.identifier.doi10.1051/epjconf/201817701004cs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/2100-014X/cs
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Creative Commons Attribution 4.0 International
Except where otherwise noted, this item's license is described as Creative Commons Attribution 4.0 International