Optimized Second-Order Dynamical Systems and Their RLC Circuit Models with PWL Controlled Sources
Abstract
Complementary active RLC circuit models with a voltage-controlled voltage source (VCVS) and a current-controlled current source (CCCS) for the second-order autonomous dynamical system realization are proposed. The main advantage of these equivalent circuits is the simple relation between the state model parameters and their corresponding circuit parameters, which leads also to simple design formulas.
Keywords
Dynamical systems, second-order systems, state mo-dels, active equivalent circuits, PWL controlled sour-ces, optimized design formulas.Persistent identifier
http://hdl.handle.net/11012/58053Document type
Peer reviewedDocument version
Final PDFSource
Radioengineering. 2004, vol. 13, č. 3, s. 13-17. ISSN 1210-2512http://www.radioeng.cz/fulltexts/2004/04_03_13_17.pdf