Svázání fyziologického modelu s modelem tepelného komfortu

Coupling of the Models of Human Physiology and Thermal Comfort

Thumbnail
View/Open
final-thesis.pdf (5.415Mb)
thesis-1.pdf (1.436Mb)
review_61249.html (1.672Kb)
Author
Pokorný, Jan
Advisor
Jícha, Miroslav
Referee
Masaryk, Michal
Kratochvíl, Zdeněk
Grade
P
Altmetrics
Metadata
Show full item record
Abstract
Disertační práce se zabývá vnitřním prostředím a tepelným komfortem v kabinách automobilů. V Dymole/Modelice byl vytvořen Model tepelné zátěže kabiny pro studium vlivů různých parametrů okolního prostředí na mikroklima uvnitř kabiny. Model byl validován na základě osmi experimentů v klimatické komoře i ve skutečných provozních podmínkách. Hlavním cílem práce bylo vytvořit model pro predikci tepelného komfortu v nehomogenním prostředí, který je použitelný i pro prostředí kabin automobilů. V Dymole/Modelice byl vytvořen Svázaný model tepelného komfortu, který umožňuje vyhodnotit celkový tepelný komfort na základě lokálních parametrů okolního prostředí a osobních faktorů člověka. Model byl validován na 16 různých scénářích převzatých z literatury. Navíc za pomoci programu Theseus-FE byly vytvořeny tři modelové případy reprezentující asymetrickou zátěž od slunečního záření v kabině automobilu. Predikce Svázaného modelu byla porovnána s Fialovým modelem a s výsledky experimentů. Svázaný model predikoval střední teplotu pokožky dostatečně přesně pro klidné aktivity v neutrálním a teplém prostředí. V chladném prostředí byly odchylky střední teploty pokožky od měření větší a predikovaná vnitřní teplota příliš závislá na teplotě okolí. Pro vyšší intenzity vykonávané činnosti byla predikovaná střední teplota pokožky příliš vysoká.
 
The thesis deals with car cabin environment and thermal comfort inside. A car cabin heat load model was developed in Dymola/Modelica to investigate influence of ambient environmental parameters. The model was validated on the data set of eight test cases measured in a climatic chamber and in a real traffic. The main objective of the thesis was to develop a human thermal comfort model suitable for non-homogenous environments and for a car cabin environment especially. The Coupled model of human physiology and thermal comfort was developed in Dymola/Modelica. The model allows predicting an overall human thermal comfort from local boundary conditions representing ambient and personal factors. The model was validated by 16 test cases taken from experiments in literature. Moreover three test cases were created in Theseus-FE to consider an asymmetrical heat load from Sun rays inside a car cabin. Prediction of the Coupled model was compared with Fiala model and experimental data. The Coupled model predicted mean skin temperature for moderate activities in neutral and warm environment well. In cold environment a predicted core temperature was very affected by ambient temperature and during high activity exercises, the predicted mean skin temperature was too high.
 
Keywords
Prostředí v kabinách automobilů, Tepelná zátěž kabiny, Tepelný komfort, Model tepelného komfortu, Model fyziologie člověka, Car cabin environment, Cabin heat load, Thermal comfort, Thermal comfort model, Human physiology model
Language
čeština (Czech)
Study brunch
Konstrukční a procesní inženýrství
Composition of Committee
Date of defence
2012-09-19
Process of defence
DP řeší problematiku vnitřního prostředí a tepelného komfortu v kabinách automobilů. Řešené téma je aktuální. Výsledky jsou aplikovatelné pro kabiny dopr. prostředků s dyn. změnami fyz. parametrů vnitřního prostředí i okolních podmínek.
Result of the defence
práce byla úspěšně obhájena
Persistent identifier
http://hdl.handle.net/11012/6317
Source
POKORNÝ, J. Svázání fyziologického modelu s modelem tepelného komfortu [online]. Brno: Vysoké učení technické v Brně. Fakulta strojního inženýrství. 2012.
Collections
  • 2012 [45]
Citace PRO

Portal of libraries | Central library on Facebook
DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback | Theme by @mire NV
 

 

Browse

All of repositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Portal of libraries | Central library on Facebook
DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback | Theme by @mire NV