Implementation and verification of the PMSM stator interturn short fault detection algorithm

View/ Open
Date
2017-09-14Alternative metrics PlumX
http://hdl.handle.net/11012/70210Altmetrics
10.23919/EPE17ECCEEurope.2017.8099080
http://hdl.handle.net/11012/70210
http://hdl.handle.net/11012/70210
Metadata
Show full item recordAbstract
This paper discusses the stator winding interturn short fault detection for three phase Permanent Magnet Synchronous Machines (PMSMs). The implementation of the Extended Kalman filter (EKF)-based fault detection algorithm is discussed. The implemented algorithm was verified with the emulated fault during different operating conditions of the drive. Measurements on a real PMSM and the implementation verification are the most important objectives of the article.
Persistent identifier
http://hdl.handle.net/11012/70210Document type
Peer reviewedDocument version
PostprintSource
19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe) 2017. 2017, p. P.1-P.10.http://ieeexplore.ieee.org/document/8099080/