Mathematical model of mechanical testing of bone-implant (4.5 mm LCP) construct
(University of Veterinary and Pharmaceutical Sciences in Brno, 2012-09-17)
The study deals with the possibility of substituting time- and material-demanding mechanical testing of a bone defect fixation by mathematical modelling. Based on the mechanical model, a mathematical model of bone-implant ...