Communication and Powering Scheme for Wireless and Battery-Less Measurement

Loading...
Thumbnail Image
Date
2012-04
ORCID
Advisor
Referee
Mark
Journal Title
Journal ISSN
Volume Title
Publisher
Společnost pro radioelektronické inženýrství
Abstract
The paper presents solution for wireless and battery-less measurement in the enclosed areas. The principle is based on passive RFID, nevertheless this paper is focused on high power-demanding applications such as MEMS accelerometers, gas sensors, piezoresistive strain gauges, etc. Standard FRID communication scheme (sensing the input current change on the primary side) cannot be used in this case, because the communication channel is overloaded by the high power load. Paper presents possible solution which is based on the dual frequency scheme – one frequency for powering and other for the communication. This is ensuring capability for measurement up to several centimeters on the frequency bands 125 kHz and 375 kHz. It can be suitable for continual measurement in isolated systems such as the rotating objects, concrete walls, enclosed plastic barrels, high temperature chambers etc.
Description
Citation
Radioengineering. 2012, vol. 21, č. 1, s. 239-245. ISSN 1210-2512