Lumbar Interbody Fusion Conducted on a Porcine Model with a Bioresorbable Ceramic/Biopolymer Hybrid Implant Enriched with Hyperstable Fibroblast Growth Factor 2

dc.contributor.authorKrtička, Milancs
dc.contributor.authorPlánka, Ladislavcs
dc.contributor.authorVojtová, Lucycs
dc.contributor.authorNekuda, Vladimírcs
dc.contributor.authorŠťastný, Přemyslcs
dc.contributor.authorSedláček, Radekcs
dc.contributor.authorBřínek, Adamcs
dc.contributor.authorKavková, Michaelacs
dc.contributor.authorGöpfert, Eduardcs
dc.contributor.authorHedvičáková, Věracs
dc.contributor.authorRampichová, Michaelacs
dc.contributor.authorKřen, Leošcs
dc.contributor.authorLišková, Květoslavacs
dc.contributor.authorIra, Danielcs
dc.contributor.authorDorazilová, Janacs
dc.contributor.authorSuchý, Tomášcs
dc.contributor.authorZikmund, Tomášcs
dc.contributor.authorKaiser, Jozefcs
dc.contributor.authorStarý, Davidcs
dc.contributor.authorFaldyna, Martincs
dc.contributor.authorTrunec, Martincs
dc.coverage.issue7cs
dc.coverage.volume9cs
dc.date.accessioned2021-11-12T22:56:39Z
dc.date.available2021-11-12T22:56:39Z
dc.date.issued2021-06-25cs
dc.description.abstractAn experimental animal study was designed to investigate the intervertebral fusion efficiency and safety of a bioresorbable ceramic/biopolymer hybrid implant enriched with FGF2-STAB(R) in comparison with a tricortical bone autograft used as a gold standard. Twenty-four experimental pigs underwent L2/3 discectomy with implantation of either the tricortical iliac crest bone autograft or the bioresorbable hybrid implant (BHI) followed by lateral intervertebral fixation. The quality of spinal fusion was assessed by micro-computed tomography (micro-CT), biomechanical testing, and histological examination at both 8 and 16 weeks after the surgery.en
dc.description.abstractExperimentální studie na zvířatech byla navržena tak, aby zkoumala účinnost a bezpečnost meziobratlové fúze a biologicky resorbovatelného hybridního implantátu z keramiky/biopolymeru obohaceného o FGF2-STAB (R) ve srovnání s trikortikálním kostním autograftem používaným jako zlatý standard. Dvacet čtyři experimentálních prasat podstoupilo discektomii L2/3 s implantací buď trikortikálního autograftu kosti kyčelní, nebo bioresorbovatelného hybridního implantátu (BHI) s následnou laterální intervertebrální fixací. Kvalita spinální fúze byla hodnocena mikropočítačovou tomografií (mikro-CT), biomechanickým testováním a histologickým vyšetřením v 8. a 16. týdnu po operaci.cs
dc.formattextcs
dc.format.extent733-758cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationBiomedicines. 2021, vol. 9, issue 7, p. 733-758.en
dc.identifier.doi10.3390/biomedicines9070733cs
dc.identifier.issn2227-9059cs
dc.identifier.other172841cs
dc.identifier.urihttp://hdl.handle.net/11012/202260
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofBiomedicinescs
dc.relation.urihttps://www.mdpi.com/2227-9059/9/7/733cs
dc.rightsCreative Commons Attribution 4.0 Internationalcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/2227-9059/cs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectmicro-CTen
dc.subjectbiomechanicsen
dc.subjecthistologyen
dc.subjectanimal modelen
dc.subjectlumbar spinal fusionen
dc.subjecttissue engineeringen
dc.subjectautograften
dc.subjectceramicen
dc.subjectcollagenen
dc.subjectFGF2en
dc.subjectmikro-CT
dc.subjectbiomechanika
dc.subjecthistologie
dc.subjectzvířecí model
dc.subjectlumbální spinální fúze
dc.subjecttkáňové inženýrství
dc.subjectautograf
dc.subjectkeramika
dc.subjectkolagen
dc.subjectFGF2
dc.titleLumbar Interbody Fusion Conducted on a Porcine Model with a Bioresorbable Ceramic/Biopolymer Hybrid Implant Enriched with Hyperstable Fibroblast Growth Factor 2en
dc.title.alternativeLaterální mezitělová fúze na bederní páteři provedena na prasečím modelu s biologicky resorbovatelným keramicko/biopolymerním hybridním implantátem obohaceným o hyperstabilní růstový faktor fibroblastů 2cs
dc.type.driverarticleen
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-172841en
sync.item.dbtypeVAVen
sync.item.insts2021.11.12 23:56:39en
sync.item.modts2021.11.12 22:49:23en
thesis.grantorVysoké učení technické v Brně. Středoevropský technologický institut VUT. Pokročilé instrumentace a metody pro charakterizace materiálůcs
thesis.grantorVysoké učení technické v Brně. Středoevropský technologický institut VUT. Pokročilé keramické materiálycs
thesis.grantorVysoké učení technické v Brně. Středoevropský technologický institut VUT. Pokročilé biomateriálycs
thesis.grantorVysoké učení technické v Brně. Fakulta strojního inženýrství. Ústav materiálových věd a inženýrstvícs
thesis.grantorVysoké učení technické v Brně. Fakulta strojního inženýrství. Ústav fyzikálního inženýrstvícs
thesis.grantorVysoké učení technické v Brně. Fakulta chemická. Ústav chemie materiálůcs
thesis.grantorVysoké učení technické v Brně. Ústav soudního inženýrství. Ústav soudního inženýrstvícs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
biomedicines0900733v2.pdf
Size:
7.87 MB
Format:
Adobe Portable Document Format
Description:
biomedicines0900733v2.pdf