Geometrical Configuration of Cabling as Factor Influencing the Reproducibility of EMC Immunity Tests
dc.contributor.author | Hallon, Jozef | |
dc.contributor.author | Kovac, Karol | |
dc.contributor.author | Szolik, Imrich | |
dc.coverage.issue | 4 | cs |
dc.coverage.volume | 15 | cs |
dc.date.accessioned | 2016-04-22T06:16:01Z | |
dc.date.available | 2016-04-22T06:16:01Z | |
dc.date.issued | 2006-12 | cs |
dc.description.abstract | The paper deals with analysis of the influence of geometrical configuration of device cabling upon voltages induced in cable interfaces. The analyzed properties are the cable height and the cable length for common mode disturbance, and the loop width for differential mode disturbance. The analysis is solved both by analytical calculation and by numerical simulation. Achieved results are compared mutually as well as with results obtained by measurements performed according to standardized procedures. Finally the analyzed parameters are ordered in correspondence of their importance for objectivity and reproducibility of immunity tests against electromagnetic field. | en |
dc.format | text | cs |
dc.format.extent | 27-33 | cs |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Radioengineering. 2006, vol. 15, č. 4, s. 27-33. ISSN 1210-2512 | cs |
dc.identifier.issn | 1210-2512 | |
dc.identifier.uri | http://hdl.handle.net/11012/57970 | |
dc.language.iso | en | cs |
dc.publisher | Společnost pro radioelektronické inženýrství | cs |
dc.relation.ispartof | Radioengineering | cs |
dc.relation.uri | http://www.radioeng.cz/fulltexts/2006/06_04_27_33.pdf | cs |
dc.rights | Creative Commons Attribution 3.0 Unported License | en |
dc.rights.access | openAccess | en |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | en |
dc.subject | Electromagnetic compatibility | en |
dc.subject | immunity testing | en |
dc.subject | multiple transmission lines | en |
dc.subject | influence of electromagnetic field | en |
dc.subject | numerical EM simulation | en |
dc.title | Geometrical Configuration of Cabling as Factor Influencing the Reproducibility of EMC Immunity Tests | en |
dc.type.driver | article | en |
dc.type.status | Peer-reviewed | en |
dc.type.version | publishedVersion | en |
eprints.affiliatedInstitution.faculty | Fakulta eletrotechniky a komunikačních technologií | cs |