Earth-Fill Dam Monitored by EIS Method during Application of Nutrient Aqueous Solution used in BioSealing Method

dc.contributor.authorPařílková, Janacs
dc.contributor.authorGjunsburgs, Borisscs
dc.contributor.authorZachoval, Zbyněkcs
dc.contributor.authorVeselý, Jaroslavcs
dc.contributor.authorMűnsterová, Zuzanacs
dc.coverage.issue1cs
dc.coverage.volume251cs
dc.date.accessioned2018-12-06T19:00:02Z
dc.date.available2018-12-06T19:00:02Z
dc.date.issued2017-10-25cs
dc.description.abstractThe paper gives short information about the results of monitoring the electrical properties of an earth-fill dam during the application of a nutrient aqueous solution used in the method BioSealing. Monitoring is carried out using a Z-meter device when applying the method of electrical impedance spectrometry and, in some cases, is part of a system of monitoring seepage through the earth-fill dam of the water reservoir by its administrator. Information about the changes that take place in the body of the dam during the movement of the water level in the reservoir or after the influence of weather changes or human activity are given through the monitored changes in the electrical parameters of the soil of the dam with time.en
dc.formattextcs
dc.format.extent1-8cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationIOP Conference Series: Materials Science and Engineering. 2017, vol. 251, issue 1, p. 1-8.en
dc.identifier.doi10.1088/1757-899X/251/1/012130cs
dc.identifier.issn1757-8981cs
dc.identifier.other144694cs
dc.identifier.urihttp://hdl.handle.net/11012/137145
dc.language.isoencs
dc.publisherIOP Publishingcs
dc.relation.ispartofIOP Conference Series: Materials Science and Engineeringcs
dc.relation.urihttp://iopscience.iop.org/article/10.1088/1757-899X/251/1/012130cs
dc.rightsCreative Commons Attribution 3.0 Unportedcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/1757-8981/cs
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/cs
dc.subjectseepageen
dc.subjectdamen
dc.subjectBioSealingen
dc.subjectelectrical impedance measurementen
dc.subjectZ-meter deviceen
dc.subjectcontinuous measurementen
dc.titleEarth-Fill Dam Monitored by EIS Method during Application of Nutrient Aqueous Solution used in BioSealing Methoden
dc.type.driverconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-144694en
sync.item.dbtypeVAVen
sync.item.insts2020.03.31 09:57:53en
sync.item.modts2020.03.31 07:44:30en
thesis.grantorVysoké učení technické v Brně. Fakulta stavební. Ústav vodních stavebcs