Check valve slam analysis in pumping station

dc.contributor.authorHimr, Danielcs
dc.contributor.authorHabán, Vladimírcs
dc.contributor.authorDokoupil, Pavelcs
dc.coverage.issue2016cs
dc.coverage.volume114cs
dc.date.accessioned2018-08-20T10:48:08Z
dc.date.available2018-08-20T10:48:08Z
dc.date.issued2016-03-28cs
dc.description.abstractPumping station supplies water for technological process. The check valve in the station was replaced with a new one. The regular test of black out discovered the high pressure pulsations accompanied with noticeable pipeline movement of discharge pipe. It was caused by late check valve closing, probably, when the back flow reached the highest possible velocity. This statement was supported with analysis of results of pressure measurement near the check valve and with a numerical simulation of the flow in the pipeline system.en
dc.description.abstractČerpací stanice dodává vodu pro technologický proces. Zpětný ventil na stanici byl nahrazen novým. Pravidelná zkouška výpadku objevila pulsace vysokého tlaku spolu s znatelným pohybem výtlačného potrubí. To bylo způsobeno pozdním zavřením zpětné klapky, pravděpodobně, když zpětný tok dosáhl nejvyšší možné rychlosti. Toto tvrzení bylo podpořeno analýzou výsledků měření tlaku poblíž zpětného ventilu a numerická simulace proudění v potrubním systému.cs
dc.formattextcs
dc.format.extent1-6cs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationEPJ Web of Conferences. 2016, vol. 114, issue 2016, p. 1-6.en
dc.identifier.doi10.1051/epjconf/201611402038cs
dc.identifier.issn2100-014Xcs
dc.identifier.other123443cs
dc.identifier.urihttp://hdl.handle.net/11012/84112
dc.language.isoencs
dc.publisherEDP Sciencescs
dc.relation.ispartofEPJ Web of Conferencescs
dc.relation.urihttp://www.epj-conferences.org/articles/epjconf/abs/2016/09/epjconf_efm2016_02038/epjconf_efm2016_02038.htmlcs
dc.rightsCreative Commons Attribution 4.0 Internationalcs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/2100-014X/cs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectwater hammeren
dc.subjectcheck valveen
dc.subjectvodní ráz
dc.subjectzpětný ventil
dc.titleCheck valve slam analysis in pumping stationen
dc.title.alternativeAnalýza práskání zpětného ventilu v čerpací stanicics
dc.type.driverconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen
sync.item.dbidVAV-123443en
sync.item.dbtypeVAVen
sync.item.insts2020.03.31 09:58:01en
sync.item.modts2020.03.31 07:37:51en
thesis.grantorVysoké učení technické v Brně. Fakulta strojního inženýrství. EÚ-odbor fluidního inženýrství Viktora Kaplanacs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
epjconf_efm2016_02038.pdf
Size:
1.9 MB
Format:
Adobe Portable Document Format
Description:
epjconf_efm2016_02038.pdf