dc.description.abstractPumping station supplies water for technological process. The check valve in the station was replaced with a new one. The regular test of black out discovered the high pressure pulsations accompanied with noticeable pipeline movement of discharge pipe. It was caused by late check valve closing, probably, when the back flow reached the highest possible velocity. This statement was supported with analysis of results of pressure measurement near the check valve and with a numerical simulation of the flow in the pipeline system.en
dc.description.abstractČerpací stanice dodává vodu pro technologický proces. Zpětný ventil na stanici byl nahrazen novým. Pravidelná zkouška výpadku objevila pulsace vysokého tlaku spolu s znatelným pohybem výtlačného potrubí. To bylo způsobeno pozdním zavřením zpětné klapky, pravděpodobně, když zpětný tok dosáhl nejvyšší možné rychlosti. Toto tvrzení bylo podpořeno analýzou výsledků měření tlaku poblíž zpětného ventilu a numerická simulace proudění v potrubním systému.cs
dc.formattextcs
dc.format.extent1-6cs
dc.format.mimetypeapplication/pdfcs
dc.language.isoencs
dc.publisherEDP Sciencescs
dc.relation.ispartofEPJ Web of Conferencescs
dc.relation.urihttp://www.epj-conferences.org/articles/epjconf/abs/2016/09/epjconf_efm2016_02038/epjconf_efm2016_02038.htmlcs
dc.rightsCreative Commons Attribution 4.0 Internationalcs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectwater hammeren
dc.subjectcheck valveen
dc.subjectvodní ráz
dc.subjectzpětný ventil
dc.titleCheck valve slam analysis in pumping stationen
dc.title.alternativeAnalýza práskání zpětného ventilu v čerpací stanicics
thesis.grantorVysoké učení technické v Brně. Fakulta strojního inženýrství. EÚ-odbor fluidního inženýrství Viktora Kaplanacs
sync.item.dbidVAV-123443en
sync.item.dbtypeVAVen
sync.item.insts2020.03.31 09:58:01en
sync.item.modts2020.03.31 07:37:51en
dc.coverage.issue2016cs
dc.coverage.volume114cs
dc.identifier.doi10.1051/epjconf/201611402038cs
dc.rights.accessopenAccesscs
dc.rights.sherpahttp://www.sherpa.ac.uk/romeo/issn/2100-014X/cs
dc.type.driverconferenceObjecten
dc.type.statusPeer-revieweden
dc.type.versionpublishedVersionen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Creative Commons Attribution 4.0 International
Except where otherwise noted, this item's license is described as Creative Commons Attribution 4.0 International